LED street light pole height and spacing design method

LED street light pole

LED street light pole height and spacing design method

Abstract for LED street light pole: The average illuminance of the road surface is one of the evaluation indexes of the city’s motor vehicle traffic roads and sidewalk lighting, and it is also a vital reference indicator for street lamp configuration. A city road should be configured or replaced with LED street lamps. Technically, it first involves the calculation of relevant indicators of lighting. Calculating with the “use factor” method is one of the more straightforward and more effective means.

The formula calculated by the “use factor” method is entirely the same as the conclusion of the study of traditional lighting theory. What we need to do is to input some experimental or theoretical data of the LED street lamp into the formula, get the result and compare it with the requirements of the road lighting design standard. These calculations are also necessary for the design, development, improvement, improvement, and marketing of LED street lamps.

First, concept

The use factor (U) is the ratio of the light flux directly on the road surface to the luminous flux emitted by all the light sources and is related to the height, elevation angle, arrangement, and road width of the street light fixture.

The luminous flux (Φ) is the sum of the energy emitted by the light source and received by the human eye. Indicates the amount of radiant energy per unit of time in lm. Other methods of expression: cd.sr (cd is the unit of luminous intensity: Candela. Sr is a unit of solid angle spherical power.

Illuminance (E) is the ratio of the luminous flux to the illuminated area, in lux lx. 1lx means that the flux of 1lm is evenly distributed over an area of 1 square meter of energy, i.e., lm/m2.

LED street light pole the average road surface illuminance (Eav) is the average value of the illuminance at each point measured or calculated at a predetermined position on the road surface by the relevant regulations.

The maintenance factor (k) is the ratio of the average illuminance or the average luminance on a predetermined surface after the lighting device is used for a specified period to the average illuminance or the average luminance obtained on the same surface when the device is newly mounted under the same conditions.

The installation height (H) of the luminaire is the vertical distance from the light center of the luminaire to the road surface.

The installation spacing (S) of the luminaire is the distance between two adjacent luminaires measured along the centerline of the road.

The cantilever length (XL) is the horizontal distance from the light center of the lamp to the edge stone adjacent to the side, that is, the horizontal distance that the filament extends or retracts into the edge stone.

The effective road width (Weff) for LED street light pole is the breadth of the theoretical road surface used for road lighting design. It is related to the actual width of the road, the cantilever length of the luminaire, and the layout of the luminaires.

International LED Industry Technology Exhibition

International LED Industry Technology Exhibition LED street lamps

At the “China (Shanghai) International LED Industry Technology Exhibition” opened on July 7th at the New International Expo Center, the “LED Streetlight Rating Competition” launched by the Organizing Committee has attracted a lot of attention. LED street lamps collectively from all over the country Appearance, in the light efficiency, color temperature, uniformity and other technical parameters to compete. The competition is one of the preparations for Shanghai to develop LED technology standards, laying the foundation for LED technology to enter the homes of ordinary people indeed.

Semiconductor lighting (LED), as a new type of solid-state light source, has shown energy-saving effects in more and more lighting fields. For example, instead of neon landscape lighting, it can save energy by 70%. LED traffic lights can save energy by 80%. However, people in the industry have pointed out with concern that the LED industry has developed rapidly in recent years, but it still lacks official technical standards, resulting in mixed sectors and unfavorable for large-scale promotion.

For LED street lamps with relatively high technical difficulty, the problems caused by the lack of professional standards are particularly apparent. According to statistics, there are about 500,000 street lamps in Shanghai, of which about 350,000 are in urban areas. Semiconductor lighting is used. Currently, there is only a small demonstration section of Wuning Road. “Many outstanding LED manufacturers and integrators do not know how to design a practical street light, and the application department cannot explain specific requirements.” Regarding heat dissipation, an “open-type” lampshade was designed. However, for the street lamp, this type of “wind and rain” function is poor and is not suitable for street lighting. The organizers hope that through this “LED street light PK,” find suitable technical indicators and design programs, and then to develop the entire LED industry related professional standards to explore the way.

Semiconductor lighting

At the “China (Shanghai) International LED Industry Technology Exhibition” opened on July 7th at the New International Expo Center, the “LED Streetlight Rating Competition” launched by the Organizing Committee has attracted a lot of attention. 72 LED streetlights collectively from all over the country Appearance, in the light efficiency, color temperature, uniformity and other technical parameters to compete. The competition is one of the preparations for Shanghai to develop LED technology standards, laying the foundation for LED technology to enter the homes of ordinary people indeed.

Semiconductor lighting (LED), as a new type of solid-state light source, has shown energy-saving effects in more and more lighting fields. For example, instead of neon landscape lighting, it can save energy by 70%. LED traffic lights can save energy by 80%. However, people in the industry have pointed out with concern that the LED industry has developed rapidly in recent years, but it still lacks official technical standards, resulting in mixed sectors and unfavorable for large-scale promotion.

For LED street lamps with relatively high technical difficulty, the problems caused by the lack of professional standards are particularly apparent. According to statistics, there are about 500,000 street lamps in Shanghai, of which about 350,000 are in urban areas. Semiconductor lighting is used. Currently, there is only a small demonstration section of Wuning Road. “Many outstanding LED manufacturers and integrators do not know how to design a practical street light, and the application department cannot explain specific requirements.” Regarding heat dissipation, an “open-type” lampshade was designed. However, for the street lamp, this type of “wind and rain” function is poor and is not suitable for street lighting. The organizers hope that through this “LED street light PK,” find suitable technical indicators and design programs, and then to develop the entire LED industry related professional standards to explore the way.

LED street lamps

National standards for acceptance of poles and lamps

National standards for acceptance of poles and lamps
Lamps and lampposts, electrical light source performance instructions using material description
1.1 Lamp pole technology reference requirements
1. The central body rod is formed once, and the weld of the steel rod (Q235) must be smooth and smooth. The error of the entire rod body weld convex portion and the rod body flatness should be no more than ±1 mm. The lamp pole welding method is automatic sub-arc welding, and the coloring inspection inspection meets the requirements of the welding international standard GB/T3323-1989111. The lamp pole socketing method adopts the nail and the top wire to fix.
2. The lamppost anti-corrosion treatment is hot-dip galvanizing. The galvanized layer has a smooth and beautiful surface and a uniform gloss. No wrinkle skin, drop and zinc tumor, peeling, spots, yin and yang surface defects, zinc layer thickness of 85um or more, galvanized layer adhesion should be consistent with GB2694-98 standard, ensure that 8 years do not fade, light pole wind resistance Ability to design at 36.9 meters/second. Lamppost antiseptic life is more than 20 years.
3. The surface of the pole is sprayed with a thickness of ≧100um, the adhesion is up to GB9286-880 grade, the surface is smooth: the hardness is ≧2H, outdoor weather resistant material is used, and the sprayed plastic material is full polyester plastic powder.
4. Light pole process and acceptance standards are implemented according to national standards. Design factor 1.8. The design life of poles is more than 20 years.
5. The light pole design should facilitate the threading of the wire, and the hand hole door adopts the form of a backpack door. The gate must be smooth and smooth, and the leveling error with this rod is not more than ±1mm. The same lamp pole door and door are better interchangeable, and it meets the anti-theft and anti-rain requirements. After the bar door is cut, it is partially reinforced to primarily reach the strength of the original whole bar.
6. Appearance color: According to the owner specified color. (effect color)
1.2 Lamp pole technical standards:
Executive standard
1. GB2694-88 Lamps and lampposts hot dip galvanized body galvanized quality
2. GB10854-89 Steel Structure Welding Dimensions
3, GB77-88 carbon structural steel
4, GB1591-93 low-construction steel technology
5, GB2519-88 hot continuous rolling steel strip containing varieties
6, DL/T646-98 transmission line steel pipe manufacturing technology conditions
7, AASHT01994 pole, high pole, Lamps and lampposts traffic signal pole
1.3 Lamp pole technical parameters:
1. Taper: 12:1000
2. Straightness deviation: <0.2%
3, length deviation: <+5nlm
4. Margin deviation: +2mm
5, the body twist: <5 °
6, rod body straightness: <1mm
7, bending arm distortion: <2 °
8, the deviation of the margin of the bending arm part: <15 °
9, flange and rod body perpendicularity deviation: <1 °
10, flange welding position deviation: <2mm
11, Lamps and lampposts galvanized layer thickness: ≥ 85um
12, the pole surface spray thickness: ≥100um
13, design factor: 1.8
14, wind speed: 36.9m/s
1.4 Lamp pole technical test standard:
1. Adhesion test, cross-marking with a special adhesive tape 12 times vertical sticking without peeling.
2, galvanized layer thickness test: Take 30 points, take the arithmetic average greater than 86um.
3, salt spray resistance test: 5% NaCl, 35 °C, 96 hours no yellow rust.
4. The uniformity of the thickness of the galvanized layer was tested. The copper sulfate impregnation method was tested for six times without copper.
1.5 lamp pole, lamp full polyester plastic powder technical parameters:
1, the state of the container: uniform color, loose no agglomeration
2. Screen residue (88um%): <0.5
3, curing conditions: 180-200±2°C 10-20 minutes
4, Appearance: smooth, allowing the slight orange peel
5, coating thickness: 100um
6. Color: Standard swatches and allowable color cast range determined by both suppliers and buyers
7, gloss: high light ≥ 85%, 51-84% light, flat light 50-15%, no light <14%
8, impact strength: 50kg/cm2
9, pencil hardness ≥ 2H (no scratch)
10, adhesion (cross-cut method): 0
11. Bend test (taper shaft): 3mm pass
12. Cupping test ≥ 6mm
1.6 Lamps, lamps, and full polyester plastic powder technical parameters:
1, the state of the container: uniform color, loose no agglomeration
2. Screen residue (88um%): <0.5
3, curing conditions: 180-200±2°C 10-20 minutes
4, Appearance: smooth, allowing the slight orange peel
5. Color: Standard swatches and allowable color cast range determined by both parties of supply and demand
6, gloss: high light ≥ 85%, 51-84% light, flat light 50-15%, no light <14%
7, impact strength: 50kg/cm2
8, pencil hardness ≥ 2H (no scratch)
9, Adhesion (cross-cut method): 0
10, bending test (taper shaft): 3mm through
11. Cupping test ≥ 6mm

2.1 Lamp Technical Requirements
1. The designer and the owner jointly confirm the luminaire surface color.
2. The lamp body adopts LM6 anti-corrosion high-pressure cast aluminum, and the surface is full-polyester plastic powder. A lampshade is a high-strength tempered glass, high-temperature resistance 200&ordm; C above, high light transmittance, impact resistance. The lighting adopts a variety of light control measures and has a special light distribution to ensure sharp light above the water level, which can effectively prevent glare to the driver. The reflector is imported anodized high purity aluminum plate, after anodizing treatment, and according to the special design of the reflective bus, with a reasonable distribution of light, Lamps and lampposts energy saving, high light efficiency.
3. Anti-corrosion performance of lamps and lanterns shells, dust-proof water level IP65 above, protection against electric shock one category. The warranty period is one year.
4 lamps work environment: -35&ordm; C a +45&ordm; C
5. Luminaires adopt internal foam-removal structure lamps with anti-loose, anti-vibration lamp holder devices and corresponding anti-vibration measures, and are highly vibration-proof. The housing has separate optical and electrical chambers. Separately used to install light sources and electrical accessories. Compact, reasonable and easy to use.
6, power AC220, V (± 10%) / 50HZ attenuation.
7, lamps within the electrical appliances, light sources, the use of well-known domestic Nanjing Sale brand, provided by my full set of manufacturers, convenient for future maintenance and standardization.
8, high-grade electrical performance, sodium lamp power factor after compensation ≥ 0.85.
9. When the lamp is turned on, tools need to be opened to prevent theft.
10, electrical lamp board can be easily removed to facilitate maintenance.

2. two luminaire technical standards
1. Technical conditions of GB13037-91 fixed general lighting
2. General safety requirements and experiment for GB7000.1-2000 lamps
3, GB7001-86 lamp shell protection class classification
4, GB7003-86 lamp plating, chemical coating
5, GB7004-86 lamps and lanterns wooden box packaging technical conditions
6、Technical conditions of GB13037-91 fixed general lighting
7, QB/T1553-92 lamp corrugated carton packaging technical conditions Lamps and lampposts
8, QB/T1504-94 high-pressure sodium ballast performance requirements
9, QB/T2048-2061-94 electric light source
10. QB/1115-91 electronic trigger for high-pressure sodium bulb
11. GB13259-91 high-pressure sodium lamp
2.3 luminaire performance description
1, rated working voltage: 220V (effective value)
2, rated insulation voltage: 500V (effective value)
3, rated frequency: 50HZ
4, insulation resistance: ≧ 500MQ
5. Dielectric strength: It can withstand the test voltage of AC 50HZ and 1500V (effective value), and it should have no breakdown or flashover phenomenon for 1 minute.
6, power factor: cos & Oslash; ≧ 0.85
7, lamp protection against electric shock: Class 1
8. Connection mode: three-phase
9, lamp efficiency: 70%
10、Protection level: IP65 (depending on lighting working environment)
11, reflector material: 3002-0 high purity aluminum plate
12, lampshade material: high transparent tempered glass
13, lighting distribution curve: Lamps and lampposts special design for the road surface conditions
14, lighting appliances (ballast, trigger, capacitor insurance) are installed in the lamp

Lamps and lampposts

NB-IOT smart light pole

NB-IOT smart light pole

According to recent news, Xiong’an New District will complete the construction of the NB-IOT smart light pole demonstration project. Smart light poles will kick off the informatization construction of Xiong’an New District.

The completion of Xiong’s creative lamp pole demonstration project will realize the functions of intelligent lighting, smart perception, and intelligent management and control.

The intelligent light pole provides a bright solution for the construction of the intelligent city in Xiong’ an New District and becomes a smart city for Xiong’ an New District. Benchmarking.

The Xiong’an New District hot Xiaobian understands that Xiong’an’s lamppost will also have a “brain” to calculate and help people live a better life.

This pole integrates WiFi, cameras, weather monitors, charging piles, and other equipment.

In the future, it will also incorporate garbage cans, pit covers, and more Internet of Things detection equipment, further sharing bicycle parking, plaza dancing, and construction.

Noise problems such as construction noise provide a practical solution.

Smart light poles are becoming the first choice for ubiquitous 5G micro base stations in the city.

NB-IOT smart light pole

smart light poles

The urban IOT information platform based on smart light poles is an important part of the smart lighting platform construction and energy saving and emission reduction in the construction of smart cities. The system is led by the 1000-person plan expert Dr Song Hongwei and has a number of technological innovation industries. First, the interface is beautiful, simple and practical, and the management function is complete. It suits the needs of pain points and street lamp managers in the industry. It subverts the idea of domestic heavy hardware and light software and is compatible with solutions such as power carrier, wireless, RS485, and solar street lamps. Integrate intelligent light poles for various information device technology innovation and composite applications, including smart lighting, WIFI hotspots, environmental information collection, security and road intelligence monitoring, information release, emergency visual alarm, 4G micro base station, and electric vehicle intelligent charging piles, etc. With multiple functions, the system can achieve energy savings of up to 40%, which not only realizes the smart management of the city but also completes the energy saving and emission reduction tasks that the country strongly advocates. Currently, the system has been promoted to more than 50 countries and more than 100 cities around the world. Fangda Intelligent Control is committed to building an international brand of smart lighting.

What is the size of the general advertising pole?

What is the size of the general advertising pole?

1, single size is 150 * 40 or 120 * 35, these two are more common, depending on the thickness and height of the light pole decision.
2. advertising pole is an essential form of advertising. Advertising pole is mainly used for advertising promotion on both sides of the road. It is mainly aimed at vehicle personnel and passersby whose objects are on the way. It is achieved through large-length and large-scale advertising pole. Advertising effectiveness.